Hero Image for Barking College  - RWP, Structural Engineers, Concrete structure engineers, School design structural engineers, Qualified structural engineers,  Commercial Structural Engineers, Structural engineering surrey, Commercial Engineers, Structural engineering Dorking, RWP structural engineers, Residential Engineers,  Residential Structural Engineers
Image number 0 for Projects -  Residential Structural Engineers, School design structural engineers, Residential Engineers, Residential & Apartment block structural engineers,  Commercial Structural Engineers, Concrete structure engineers, RWP, Structural Engineers, Commercial Engineers, Structural engineering surrey, Structural Engineering firm, RWP structural engineers
Image number 1 for Projects - Residential & Apartment block structural engineers, Qualified structural engineers, Residential Engineers, Structural engineering surrey,  Commercial Structural Engineers, RWP structural engineers, Structural Engineering firm, RWP, Structural Engineers, Chartered and structural engineers,  Residential Structural Engineers, Commercial Engineers
Image number 2 for Projects - Residential & Apartment block structural engineers, Structural Engineering firm, Structural Engineers, Commercial Engineers, RWP, Structural engineering Dorking, School design structural engineers, Concrete structure engineers, Chartered and structural engineers,  Residential Structural Engineers, Structural engineering surrey, RWP structural engineers
Image number 3 for Projects - Concrete structure engineers, Structural engineering Dorking, RWP, Commercial Engineers,  Residential Structural Engineers, School design structural engineers, Residential & Apartment block structural engineers, Structural Engineers,  Commercial Structural Engineers, Residential Engineers, RWP structural engineers, Chartered and structural engineers

Barking College


Client: Barking College

This project involved the full structural package, drainage, highways and car-parking zones.


The original structure of portalised frames was estimated by design at approximately 140 tonnes.


Our approach, given the 7.0 m x 7.0 m grid, was to use tubular columns on cantilevers with roof beams spanning over the top. The beams overrun with simple joints along the length where moment forces are lowest. Therefore the roof beams could be designed as continuous making them five times more stiff.


This simplified structure reduced the original tonnage estimate by more than 100 tonnes.

Image number 0 for Projects - Structural engineering Dorking, Residential & Apartment block structural engineers,  Residential Structural Engineers, Structural Engineering firm, Structural Engineers, RWP, Concrete structure engineers, Structural engineering surrey, Commercial Engineers,  Commercial Structural Engineers, Residential Engineers, School design structural engineers
Image number 1 for Projects - School design structural engineers, Qualified structural engineers, Structural Engineering firm, RWP,  Commercial Structural Engineers, Structural engineering surrey, Residential Engineers, Residential & Apartment block structural engineers, Chartered and structural engineers, Commercial Engineers, Structural engineering Dorking, Concrete structure engineers
Image number 2 for Projects - Structural engineering surrey, Concrete structure engineers, Chartered and structural engineers, Residential Engineers, RWP, RWP structural engineers, Structural Engineering firm, Structural Engineers,  Commercial Structural Engineers, Residential & Apartment block structural engineers, Commercial Engineers, School design structural engineers
Image number 3 for Projects - Residential Engineers,  Residential Structural Engineers, RWP structural engineers, RWP, Structural engineering surrey,  Commercial Structural Engineers, Chartered and structural engineers, Residential & Apartment block structural engineers, Concrete structure engineers, Structural Engineering firm, Commercial Engineers, Qualified structural engineers